Search results for "Fricke gel"
showing 10 items of 20 documents
GEL DOSIMETERS FOR RADIOTHERAPY APPLICATIONS: RESULTS OF A “RESEARCH PROJECT OF NATIONAL INTEREST” (PRIN)
2016
Introduction: Gel dosimeters for three-dimensional mapping of radiotherapy doses were introduced at Yale University in the mid-1980’s. Soon after, research and development in this field also started in Italy. Early work was done at the Istituto Superiore di Sanità and at the Universities of Pisa and Milan. Several institutes now collaborate on this topic with the goal of developing new formulations of hydrogel matrices with improved characteristics of stability, sensitivity and spatial resolution compared to those of earlier Fricke-gel and polymer-gel systems. Materials and methods: Contrary to earlier gels based on natural gelling agents, such as porcine skin gelatin and/or agarose, which …
Nuovi gel di Fricke ad alta sensibilità e bassa diffusione per dosimetria 3D tramite MRI
2017
One of the most recent and promising developments in radiotherapy dosimetry was the introduction of 3D radiationsensitive gels. These gels present tissue equivalent composition and density, so they also serve as phantoms, and their response is largely independent of radiation quality and dose rate. Some gels are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gel). In this work Fricke gel dosimeters produced with a matrix of poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). This work focused on the analysis of the temporal diffusion of ferric ions through PVA-GT…
The impact of self-oxidation on the dosimetric performance of ferrous-sulfate/xylenol-orange gels
2015
Since their introduction in the 1980’s, most of the research on ferrous-sulfate gel dosimeters has aimed at minimizing the ferric ion diffusion phenomena that blur the 3D distribution of the signal. However, equally important are the spontaneous oxidation effects, which alter the sensitivity of the gels over time. In some gels, this effect is very pronounced and must be accounted for even when production, calibration and use of the gels are separated by just a few days. In other cases, the effect is much milder, but should still be properly accounted for when gels are used over a long period a time, such as in the proposed monitoring of adaptive radiotherapy treatments. Our work examined an…
Fricke gel, electron spin resonance and thermoluminescence for integration and intercomparison of measurements in NCT dosimetry
2014
PVA-GTA Fricke gel: studio della risposta NMR in funzione della concentrazione degli additivi e studi preliminari con scanner MRI 7 T
2016
Sono stati analizzati tramite rilassometria NMR ed acquisizioni MRI dosimetri gel di tipo Fricke realizzati utilizzando un'innovativa matrice gel sintetica e tessuto equivalente: Polyvinyl alcohol (PVA) attivando chimicamente il processo di gelificazione tramite l'aggiunta di Glutaraldehyde (GTA). Questi gel sono stati irradiati con fasci di fotoni (LINAC) nel range 0--20 Gy. Per valutare la sensibilità a fotoni è stata studiata la dipendenza dei tempi di rilassamento nucleari dalla dose e dalla concentrazione di ferro nei gel. Inoltre è stata monitorata la stabilità del segnale dopo l'irraggiamento. Acquisizioni preliminari MRI con uno scanner MRI da 7 T sono state affiancate alle misure N…
Testing and calibration of ESR response of Fricke gel dosimeters in mixed neutron-gamma fields
2013
Diffusion and sensitivity characteristics of a chemically cross-linked PVA-Fricke gel dosimeter
2016
Introduction: Current radiotherapy techniques implement treatment plans based on volumetric distributions of dose with complex shapes and sharp gradients. The agreement between these plans and the dose that is truly delivered is very challenging to verify. Thus, there is the need for a dosimetric system that is truly three dimensional, sensitive to radiation in each point and tissue equivalent. In this framework, great interest is encountered by radio-chromic gel dosimeters. In order to address the limitations of gels based on natural matrices, some investigators have proposed dosimeters based on poly vinyl alcohol (PVA) made by freezing-thawing cycles. Even though these gels have a low dif…